Institutional Repository of Key Laboratory of Marine Environmental Corrosion and Bio-fouling, IOCAS
Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid | |
Zhang, Qiaoxia1,2; Lyu, Haoyuan1,2; Li, Ning1,2; Liu, Qing1,2; Zhang, Xianxi3; Zhang, Xiao4; Wang, Xiutong5; Qingyun, Liu1,2 | |
2020-09-10 | |
发表期刊 | ELECTROCHIMICA ACTA |
ISSN | 0013-4686 |
卷号 | 354页码:9 |
通讯作者 | Wang, Xiutong() ; Qingyun, Liu(qyliu@sdust.edu.cn) |
摘要 | In this work, a sensitive signal-off photoelectrochemical (PEC) thrombin aptasensor with satisfying specificity is proposed, in which the evident initial photocurrent response is produced by the photoanode and the signal amplification strategy toward the target is based on the specific bio-affinity properties between thrombin and their aptamers. The photoanode was fabricated with uniform TiO2 nanotube arrays decorated with CuOx and perylene-3,4,9,10-tetracarboxylic acid (PTCA). After the decoration of CuOx and PTCA, both possessing a strong absorption in visible region, the photocurrent response is improved greatly. Pt nanoparticles were modified on the photoanode electrode to immobilize thrombin aptamers, which could obviously improve the conductivity of the photoanode electrode owing to the excellent conductivity of Pt nanoparticles. The non-conductive complex leads to dramatical decrease in the photocurrent value due to the steric hinder effect. Based on the joint action of evident photocurrent response of photoanode and significant signal amplification strategy, the aptasensor in this project offers a wide linear range from 0.0003 nM to 10 nM, with a detection limit (3S/N) of thrombin down to 55 fM. Moreover, the as-fabricated aptasensor exhibits acceptable selectivity and stability, providing a meaningful attempt for the detection of thrombin. (C) 2020 Elsevier Ltd. All rights reserved. |
关键词 | Thrombin Photoelectrochemical aptasensor TiO2/CuOx Perylene-3,4,9,10-tetracarboxylic acid |
DOI | 10.1016/j.electacta.2020.136774 |
收录类别 | SCI |
语种 | 英语 |
资助项目 | National Natural Science Foundation of China[21971152] ; Natural Science Foundation of Shandong Province[ZR2018MB002] |
WOS研究方向 | Electrochemistry |
WOS类目 | Electrochemistry |
WOS记录号 | WOS:000569145000012 |
出版者 | PERGAMON-ELSEVIER SCIENCE LTD |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/168799 |
专题 | 海洋环境腐蚀与生物污损重点实验室 |
通讯作者 | Wang, Xiutong; Qingyun, Liu |
作者单位 | 1.Shandong Univ Sci & Technol, Coll Chem & Biol Engn, State Key Lab Min Disaster Prevent & Control Cofo, Qingdao 266590, Peoples R China 2.Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China 3.Liaocheng Univ, Shandong Prov Key Lab, Collaborat Innovat Ctr Chem Energy Storage & Nove, Sch Chem & Chem Engn, Liaocheng 252059, Shandong, Peoples R China 4.Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China 5.Chinese Acad Sci, Key Lab Marine Environm Corros & Biofouling, Inst Oceanol, Qingdao 266071, Peoples R China |
通讯作者单位 | 中国科学院海洋研究所 |
推荐引用方式 GB/T 7714 | Zhang, Qiaoxia,Lyu, Haoyuan,Li, Ning,et al. Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid[J]. ELECTROCHIMICA ACTA,2020,354:9. |
APA | Zhang, Qiaoxia.,Lyu, Haoyuan.,Li, Ning.,Liu, Qing.,Zhang, Xianxi.,...&Qingyun, Liu.(2020).Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid.ELECTROCHIMICA ACTA,354,9. |
MLA | Zhang, Qiaoxia,et al."Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid".ELECTROCHIMICA ACTA 354(2020):9. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
1-s2.0-S001346862031(3000KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论