摘要A solid sampling method for the determination of lead in foods (including grains, vegetables and seafoods) using electrothermal vaporization atomic fluorescence spectrometry was established. The method introduced samples using electrothermal vaporization by quartz furnace and used on-line ashing and vaporization to remove matrix interferences for the specific trap of lead. It was proven by the certified reference material (CRM) and the recovery rate of the standards that the electrothermal vaporization was stable and there was no effect for sampling difference. The best operating program and parameters for the new method included ashing (850 C, 160 s), vaporization and trap (1050 degrees C, 80 s; 800 degrees C, 10 s), release (800 degrees C, 10 s), and mixed Ar + H-2 (85:15%, v/v) as carrier gas with flow rate of 500 mL/min. The relative standard deviations of repeated Pb measurements in CRMs were all below 5.0%, and the recovery rate ranged from 90.0 - 110.0%. The limit of detection (LOD) for the new method was 3.0 pg and the limit of quantification (LOQ) was 10.0 pg. The total time of analysis was less than 6 min. No significant differences existed between the results measured by the new method and microwave ICP-MS.
关键词Lead Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry Foods
收录类别SCI
语种英语
WOS记录号WOS:000384277400014
引用统计
被引频次:8[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
版本出版稿
条目标识符http://ir.qdio.ac.cn/handle/337002/135851
专题实验海洋生物学重点实验室
作者单位1.Chinese Acad Fishery Sci, Yellow Sea Fishery Res Inst, Nanjing Rd 106, Qingdao 266071, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Nanhai Rd 7, Qingdao 266071, Peoples R China
3.Yancheng Hairui Food Co Ltd, Dafeng 224005, Peoples R China
推荐引用方式
GB/T 7714
Shang, Derong,Zhao, Yanfang,Zhai, Yuxiu,et al. Direct Determination of Lead in Foods by Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry[J]. ANALYTICAL SCIENCES,2016,32(9):1007-1010.
APA Shang, Derong,Zhao, Yanfang,Zhai, Yuxiu,Ning, Jinsong,Duan, Delin,&Zhou, Yongdong.(2016).Direct Determination of Lead in Foods by Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry.ANALYTICAL SCIENCES,32(9),1007-1010.
MLA Shang, Derong,et al."Direct Determination of Lead in Foods by Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry".ANALYTICAL SCIENCES 32.9(2016):1007-1010.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Direct Determination(473KB)期刊论文出版稿限制开放CC BY-NC-SA浏览
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Shang, Derong]的文章
[Zhao, Yanfang]的文章
[Zhai, Yuxiu]的文章
百度学术
百度学术中相似的文章
[Shang, Derong]的文章
[Zhao, Yanfang]的文章
[Zhai, Yuxiu]的文章
必应学术
必应学术中相似的文章
[Shang, Derong]的文章
[Zhao, Yanfang]的文章
[Zhai, Yuxiu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Direct Determination of Lead in Foods by Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。